Thermal mass cycling refrigerated air dryers

Air flow 38 – 237 m³/min

The new thermal mass cycling refrigerated air dryers DE ETM are the optimum choice for treating high compressed air flow in all applications that need low energy consumption, dependability, and great performance.

↗Send Inquiry
Request technical details, pricing and availability from our engineering team.
Category: Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Description

Energy savings:

The DE ETM thermal mass technology enables the units to adapt their own energy consumption to the actual load, resulting in approximately 80% savings as compared to typical air dryers. DE ETM’s energy-saving capacity can be further enhanced by activating the DDF system, an innovative microprocessor control technology that automatically regulates the DEW point based on the ambient temperature, in order to lower the absorbed power of the compressors.

New high efficiency heat exchanger

The new high-efficiency heat exchanger, which has an enhanced countercurrent exchange and an integrated air-to-air exchanger, ensures low energy usage and minimal pressure drops. The exact design and integrated demister separator ensure a precise DEW point as well as protection against condensation freezing.

de etm

Maximum reliability

DE ETM air dryers include a dependable industrial chiller whose tank serves as thermal mass. The careful selection of high-quality materials and components assures that the dryer will last for a long period, decreasing the risk of damage.

DE ETM Grafico Portate Update

High air flows

DE ETM’s heat exchangers use specific bar and plate technology to function with compressed air loads ranging from 38 to 237 m³/min while maintaining exact DEW points in all situations and negligible pressure drops.
UL508A power supply: 460V/3/60Hz.

Technical specifications:

  1. Liquid thermal mass technique (water-propylene glycol) for controlling drying capacity and maximizing energy savings;

  2. Two-in-one aluminum heat exchanger intended to enhance heat transfer coefficient (counter flow) and high efficiency large demister separator;

  3. R410A is an environmentally benign refrigerant (ODP=0).

  4. High-efficiency scroll compressors with crankcase heaters;

  5. Microprocessor control with an integrated DDF capability to dynamically adjust the dew point;

  6. The standard phase monitor protects against phase loss and reversal.

  7. IP54 protection rating is suited for outdoor installation.

  8. RS485 supervision kit for connecting to BMS supervision systems using the RS485 electrical standard and the MODBUS protocol.

  9. UL508A power supply: 460V/3/60Hz.