ENER DRYER

Biogas dryers

Biogas flow 0,8 – 78,3 m³/min.

EnerDryer is specifically intended to dry the Biogas that will be used to power the co-generators and is highly compact and appropriate for outdoor installation. The dryer is supported by a strong galvanized steel beam structure, which includes an industrial chiller with an integrated hydraulic module and a thermally insulated drying system made up of a gas/water heat exchanger, an economizer exchanger, and a condensate separation and drain system. All parts in touch with the biogas are in stainless steel, which ensures stable and secure functioning over time.

↗Send Inquiry
Request technical details, pricing and availability from our engineering team.
Category: Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Description

Benefits:

  1. The shell and tube heat exchangers made of AISI 304 are corrosion-resistant (biogas side).

  2. Plug-and-play configuration for easy and quick installation.

  3. Higher combustion efficiency in the CHP cogenerator, with reduced biogas usage;

  4. Increased the duration of CHP cogenerator lubricating oil.

  5. Eliminating condensate from biogas distribution lines reduces freezing concerns;

  6. Reduction of corrosive phenomenon produced by the mixture of condensate, CO2, and H2S;

  7. Reduced plant downtime and maintenance expenses.

  8. Improved performance and duration of dry biogas filtering devices.

  9. The “washing” effect removes some of the contaminants present in the biogas.

Technical Specifications:

  1. Biogas side shell and tube heat exchangers in AISI 304

  2. Chiller with Eurovent-certified performance

  3. Integrated economizer heat exchanger, totally of stainless steel: minimizes energy usage and maintains the dew point;

  4. The double demister separator with twin condensate exits ensures an excellent dew point and optimal efficiency.

  5. Heat-insulated standard heat exchangers for maximum system efficiency.

  6. Designed for exterior installations.

  7. Special and tailored versions are available upon request.

Accessories & Kits:

  1. AISI 304 ENERDRAIN automatic condensate drain.

  2. ATEX biogas blower.

  3. Modbus RS485 supervisor system.