Description
Our Data Centre Cooling Solutions
Chilled Water Pump Skids
- Primary chilled-water pump skids
- Secondary chilled-water pump skids
- Circulation pump packages
- Duty/standby pump configurations
- Variable-speed pumping systems
- Automated pressure and flow control
Process Cooling Water Systems
- Closed-loop cooling water systems
- Process cooling water circulation
- Equipment cooling systems
- Temperature-controlled water circulation
- Cooling water pumping packages
Heat Transfer Skids
- Heat exchanger skids
- Plate heat exchanger packages
- Shell & tube heat exchanger systems
- Cooling-water heat transfer packages
- Primary/secondary heat transfer systems
Booster Pump Skids
- Chilled-water booster systems
- Pressure boosting packages
- Cooling-water booster skids
- Automated pump sequencing
- Variable-flow pumping systems
Automation & Controls
- PLC-based cooling control
- HMI operator interface
- Pump sequencing
- Variable Frequency Drive (VFD) control
- Flow monitoring
- Pressure monitoring
- Temperature monitoring
- Differential-pressure control
- Alarm and equipment protection
- Integration with existing BMS/plant automation where required
Cooling System Applications
Aegis Projects cooling solutions can support:
- Data centres
- Server rooms
- Colocation facilities
- Cloud infrastructure facilities
- IT infrastructure
- Telecom facilities
- Network operation centres
- Critical electrical rooms
- UPS and battery cooling
- Equipment cooling systems
Customized Data Centre Cooling Systems
Cooling systems can be engineered according to:
- Required cooling capacity
- Chilled-water flow rate
- Supply and return temperatures
- Operating pressure
- Pump duty
- Required redundancy
- Heat exchanger requirements
- Pipe sizes
- Equipment layout
- Available installation space
- Automation requirements
- Existing BMS or plant control system
Systems can be designed for new data centre construction or integration with existing cooling infrastructure.
Redundancy & Reliability
For critical cooling applications, pumping and heat-transfer systems can be configured according to the required redundancy philosophy.
Possible configurations include:
- Duty/standby pumps
- Multiple operating pumps
- Automatic pump changeover
- Redundant instrumentation
- Independent control circuits
- Automatic fault detection
- Emergency alarms
- Backup equipment arrangements
The final redundancy configuration should be established according to the data centre’s design criteria and availability requirements.
Skid-Mounted Cooling Packages
Aegis Projects can integrate pumps, heat exchangers, valves, piping, instrumentation and controls onto factory-assembled skid packages.
A typical package can combine:
Pumps + Heat Exchanger + Piping + Valves + Instrumentation + VFD + PLC + HMI
This can simplify installation and reduce the amount of field fabrication required.
Engineering & Integration
Aegis Projects can provide an integrated engineering scope covering:
- Pump selection
- Heat exchanger selection
- Cooling-system design
- Skid design
- Piping layout
- Instrumentation
- Electrical panels
- VFD integration
- PLC programming
- HMI development
- Factory assembly
- Functional testing
- Factory Acceptance Testing (FAT)
- Installation support
- Start-up and commissioning assistance
Cooling packages can also be designed to communicate with existing Building Management Systems (BMS) or plant automation systems where required.
Key Benefits
- Engineered cooling-water solutions
- Reliable fluid circulation
- Automated pump control
- Variable-flow operation
- Heat exchanger integration
- Duty/standby configurations
- Compact skid-mounted packages
- Factory assembly and testing
- BMS/automation integration options
- Customized according to facility requirements
- Suitable for critical infrastructure applications
Aegis Projects for Data Centres
Aegis Projects Technology provides data centre cooling systems, chilled-water pump skids, process cooling water systems, heat transfer skids and automated pumping packages for critical infrastructure applications.
Our solutions can be engineered around the facility’s cooling capacity, flow, pressure, temperature, redundancy and automation requirements.
Build a Reliable Data Centre Cooling System
From chilled-water circulation and heat transfer to automated pumping and cooling-water management, Aegis Projects can develop customized cooling packages for data centres and other critical facilities.